Description
1-phase or 3-phase portable diesel generator features with 7.5kVA (6kW) rated output, 50Hz/60Hz 120 volt, 220 volt, 240 volt AC voltage. Electric start with 30AH 12V battery, 16L large fuel tank ensures 7 hours of continuous running, is usually used in places such as home, shops without connection to a power grid, or as emergency power supply if the grid fails.
Specifications
Model
DG7500SE
Generator
Frequency
50Hz
60Hz
AC Voltage
120V, 220V, 230V, 240V, 120/240V, 220/380V, 230/400V, 240/415V
Rated AC Output
5.6kW
6kW
Max. AC Output
6kW
6.5kW
Continuous Working Time
8h
7.3h
DC Output
12V 8.3A
Power Factor (cosΦ)
cosΦ=0.8
Alternator Type
Self-excited
Phase
Single or Three phase
Noise Level at 7m
68-72dB
Fuel Tank Capacity
16L
Starting Battery
12V 30AH*The starting batteries cannot be carried by air so you need to purchase it separately.
Certificate
CE, ISO
Engine
Model
HR188FA
Engine Type
Single-cylinder, vertical, 4-stroke air-cooled diesel engine
Bore*Stroke
88*75mm
Displacement Capacity
456cc
Fuel
0# or -10# light diesel oil
Lubrication Oil Volume
1.65L
Combustion System
Direct injection
Standard Configuration
Voltmeter*1
AC output socker*2
AC circuit breaker*1
Oil warning light*1
Oil alert*1
Optional Configuration
DC circuit breaker
Calculagraph
Big wheel
Three phase voltage
Current meter
ATS
Remote control
*Please contact us if you need the above options.
Dimensions
Dimension (L*W*H)
940*560*760mm
Gross Wight
160kg
Tips: Do not start the diesel generator with load
Before starting the diesel generator, pay attention to that the output air switch of the generator must be in the off state. After the start-up of the diesel engine of the common generator set, the temperature is low in winter after 3-5 minutes of idle operation (about 700 RPM), and the idle operation time should be appropriately extended for several minutes. After starting the diesel engine, first observe whether the oil pressure is normal and whether there is any abnormal phenomenon such as oil leakage and water leakage. (Under normal circumstances, the oil pressure must be above 0.2MPa). In case of any abnormality, stop the engine immediately for maintenance.
If there is no abnormal phenomenon, the diesel engine speed will be increased to the rated speed of 1500 rpm, at this time, the generator display frequency is 50Hz and the voltage is 400V, then the output air switch can be closed and put into use. The generator set is not allowed to operate without load for a long time. (Because long-term no-load operation will make the diesel fuel injected from the diesel engine injector not completely burn, resulting in carbon deposition, resulting in air leakage of valves and piston rings.) If it is an automatic generator set, it does not need to run at idle speed, because the automatic generator set is generally equipped with a water heater, so that the diesel engine cylinder body is always kept at about 45 ℃, and the power can be normally delivered within 8-15 seconds after the diesel engine is started.