Centrifugal water pump with maximum flow 32.5 m³/h (143 gpm), maximum head 82m (269ft), 2900rpm motor speed, horizontal structure, 0°, 90° and 180° installation angle of outlet and same diameter of inlet and outlet 40mm (1~1/ 2 inch).
Features:
The centrifugal pump has the horizontal structure. The diameter of the inlet and outlet are the same. If a protective cover is added, it can be used in the open air.
It is easy to install and maintain. No need to dismantle pipeline system, just lifting off the conjunction flat nut of vertical pump. Then all the rotor parts can be taken out.
Horizontal centrifugal pump can be operating in series and parallel connection according to the requirements of flow and head.
The installation angle of pump outlet can be 0°, 90° and 180° to meet different connection occasions.
Specification
Model: ATO-HCP-65-250
Power: 20 hp (15 kW)
Number of stages: Single stage
Input voltage: AC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
Input frequency: 50Hz/ 60Hz
Inlet diameter: 40mm (1-1/2 inch)
Outlet diameter: 40mm (1-1/2 inch)
Flow (min. flow to max. flow): 17.5 m³/ h (77gpm), 25 m³/ h (110gpm), 32.5 m³/ h (143gpm)
Head (max. head to min. head): 82m (269ft), 80m (262ft), 76.5m (251ft)
Efficiency: 39%/ 50%/ 52%
Nominal diameter of impeller: 250mm
Size: 520*795*330mm
Weight: 230kg
Dimension (mm)
Boundary dimension
h
H
L
a
A
280
520
795
100
65
Base dimension
L1
B
I
b
h1
4-φd1
560
330
510
230
100
4-φ18
Flange dimension
D
D1
n-φd
φ185
φ145
4-φ18
Tips: Centrifugal Pump Troubleshooting – Serious Vibration of Pump and Abnormal Noise.
If the centrifugal pump foundation is staleWhen vibration occurs, please firstly check if the anchor bolts of the centrifugal pump are tight. If they are not tightened, it will cause the centrifugal pump to vibrate. Please also consider whether the foundation strength of the foot is sufficient. Sometimes, due to design reasons, the soft foundation can also cause vibration.
Coupling alignmentMany centrifugal pumps are driven by couplings, and there are many types of couplings. The alignment of the normal three-paw coupling directly affects the normal operation and service life of the coupling, shaft, bearing, and machine seal.
AlignmentImproper alignment is also the common reason causing vibration. The alignment should be regulated in the specified range according to the standard strictly.
Bearing inspectionCheck if the bearing is correctly installed or damaged.
Adjustment of the rotor central positionThe water pump rotor must be concentric with the stator, otherwise friction will be generated in water pump operation, thus causing viration.
Shaft curving and rotor measurementIf the cause of the viration can not be found externally, the pump can only be disassembled. Please firstly measure and correct the bending of the shaft. After confirming to have no probblem, the rotor will be mounted, and the overall sway and scoring will be measured. If it exceeds the standard, it must be corrected.
Inspection of the dynamic and static balanceAfter the centrifugal pump is disassembled, in order to avoid vibration when the pump is turned on, the impeller should also be conducted with the static balance test.
Influence of external conditions to the water pumpWhen all the problems of the pump itself are completely eliminated, if the vibration problem can still not be solved, the influence of external conditions on the pump should also be considered. For example, the resonance caused by the natural frequency of the pump base is similar to the vibration frequency, the vibration of the pump caused by the failure of the prime motor, and the strong counterpart used for the connection between the pipeline and the pump will also probably cause abnormal vibration of the pump.