Oil-lubricated beil drive air compressor is designed with a slow-running compressor block for exceptional long service life. Cast iron cylinders with low-speed pistons have traditionally been recognized for their durability.10 hp Belt Driven Air Compressor Features
10 hp (7.5 kW) 120V 60Hz single phase motor
48 Gal., 60 Gal., 80 Gal. tank capacity for your choice
Max pressure 12.5 Bar, 175 PSI
27.4 CFM, 34.6 CFM, 40.7 CFM air delivery are available
48 gallon Air Compressor Description
Model
ZB-09125
Size
150 (L)*53 (W)*110 (H) CM
Type of the Air Copmpressor
Belt driven
Tank Capacity
48 Gal. (Can be customized)
Motor Power
10 hp, 7.5 kW (Can be customized)
Power Source
AC Power
Voltage
120V, 60Hz (Can be customized)
90×2, 65×1
90×2, 65×1
Air Delivery
700L/Min, 24.7 CFM
Maximum Pressure
12 Bar, 175 PSI
maximum Speed
920 rpm
Certification
CE, ROHS, CCC, ISO
Noise Level
with 80DB
Warranty
1 Year
Cooling Method
Air Cooling
Choose Your Air CompressorYou could choose different stage of 10 hp (7.5kW) belt driven air compressor for your requirements
Model
Gal.
kW
HP
Stage
Cylinder
L/min
RPM
PSI
CFM
Bar
Size (cm)
ZB-09125
48
7.5
10
2 stage
90×2, 65×1
700
920
175
24.7
12.5
150*53*110
ZB-10125
60
7.5
10
2 stage
95×2, 65×1
980
920
175
34.6
12.5
152*60*120
4V-105125
80
7.5
10
2 stage
105×2, 55×2
1153
750
175
40.7
12.5
153*60*120
Note: Tell us your application needs, we can customize the air compressor to meet your precise power, tank capacity, air delivery and rated voltage requirements.Installation DiagramAir Compressor Applications
Tips: How to solve the vibration of piston air compressor?The basic cause for the vibration of the piston air compressor is that it is affected by alternating load. There are two kinds of alternating loads acting on the piston air compressor device. One is the unbalanced piston inertia force, and the other is the interference force caused by pressure fluctuation of un-continuous air supply and strong gas piping.
Processing method: Vibration caused by the imbalance of the inertia force should be eliminated and reduced as much as possible from the structure of the machine. In addition, there should be strict requirements for the basic design and construction of the air compressor. The installation of the machine must comply with the regulations, so that the vibration of the machine can be reduced as far as possible, and the amplitude and vertical amplitude can be maintained within the permitted scale.
We usually take measures as follows to eliminate the device vibration caused by air pressure fluctuation. A buffer should be added near cylinder discharge pipe gas fitting. The pore plate should be set on the gas pipeline. This method is usually set applied to gas fitting where there is a long distance from the cylinder to the buffer tank. We should have reasonable installation of pipeline fulcrum by using absorber and the piping layout should be as straight as possible, especially to avoid the right angle bending.